BD AFFIRM COLLECTION INSTRUCTIONS



Bd Affirm Collection Instructions

Aptima Multitest Swab Specimen Collection Kit Hologic. Affirm VPIII Ambient Temperature Transport System (ATTS) Collection. Break ampule in ATTS reagent dropper and dispense reagent into sample collection tube. Using transport swab provided, obtain a sample from the posterior vaginal fornix. Immediately place swab in collection tube. Break swab shaft at prescored line. Press cap onto collection tube until it snaps in place., BD Affirm™ VPIII Microbial Identification test for detection of Candida, Gardnerella, Vaginal swab using the Affirm VPIII Ambient Temperature Transport System, the Affirm VPIII Sample Collection Set or the swabs provided in the Affirm VPIII Microbial Identification Test Kit. Separate swabs should be used for other tests, e.g. culture or microscopic slide samples. These sample collection.

APTIMAВ® Vaginal Swab Specimen Collection Kit hologic.com

MICROBIOLOGY NEW TESTING REGIONAL MEDICAL LABORATORY. BD BD Affirm VPIII Microbial Identification Test - Identification Tests, Model 446252, Each-A direct specimen RNA probe-based diagnostic test for the differential detection and identification of the causative agents for vaginitis. The RNA probe techn, Specimen Collection and Transport Kit BD Affirm™ VPIII TRANSPORT SYS, AMBIENT TEMP AFFIRM VPIII (10/BX 10BX/CS) Features. Affirm™ VPIII Ambient Temperature Transport is a sterile ready-to-use system intended for the collection, transport and preservation of vaginal specimens for use only with the Affirm VPIII Microbial Identification Test The Affirm VPIII AmbientTemperature Transport.

Read all instructions carefully before use. SAffirm VPIII Sample Collection Set is for single use only; reuse may cause a risk of infection and/or inaccurate results. Specimens collected with the Affirm VPIII Sample Collection Set should only be used for testing with the Affirm VPIII Microbial Identification Test. BD Affirm VPIII Vaginitis/Vaginosis Panel Overview February 2009 Associated Pathologists/PathGroup Labs is now offering the BD Affirm VPIII test for Vaginitis/Vaginosis. This test is available for samples collected using BD Affirm Ambient Temperature transport swabs and ThinPrep collected specimens.

BD Affirm™ VPIII Microbial Identification test for detection of Candida, Gardnerella, Vaginal swab using the Affirm VPIII Ambient Temperature Transport System, the Affirm VPIII Sample Collection Set or the swabs provided in the Affirm VPIII Microbial Identification Test Kit. Separate swabs should be used for other tests, e.g. culture or microscopic slide samples. These sample collection 446252 BD Affirm™ VPIII Microbial Identification Test, 24 tests 446257 BD Affirm™ VPIII Microbial Identification Test, 120 tests Danger h225 Highly flammable liquid and vapor. h302 Harmful if swallowed. h315 Causes skin irritation. h319 Causes serious eye irritation. h336 May cause drowsiness or dizziness.

BD Affirm™ VPIII Collection and Transport BD Affirm™ VPIII Ambient Temperature Collection System Figure 1 Figure 2 VAGINAL SAMPLE COLLECTION For collection of vaginal specimens for use in the BD Affirm™ VPIII Microbial Identification Test for Candida, Gardnerella and Trichomonas.See reverse side for transport procedures. Please note: The reference ranges provided in this manual and on our result reports are for adults, unless otherwise noted.

BD Affirm VPIII Collection and Transport Temperature Collection System For collection of vaginal specimens for use in the BD Affirm VPIII Microbial Identification Test for Candida, Gardnere//a and Trichomonas. See reverse side for transport procedures. VAGINAL SAMPLE COLLECTION Sample collection is a critical step. Personnel collecting vaginal fluid specimens should be well trained to … Specimen collection. Start with quality specimen collection to achieve better results. For more than 60 years, BD Life Sciences – Preanalytical Systems has advanced the science of specimen collection to help laboratory tests become the foundation for 70% of all medical decisions. 1 Today, the gold standard in sample collection is the BD Vacutainer ® product family, which U.S. hospitals rely

3.1 Instructions for indicator lights When powered on, all indicator lights will turn on for 5 seconds, and then will turn off. “HEATING”: The red indicator light indicates that the instrument is heating. Read all instructions carefully before use. SAffirm VPIII Sample Collection Set is for single use only; reuse may cause a risk of infection and/or inaccurate results. Specimens collected with the Affirm VPIII Sample Collection Set should only be used for testing with the Affirm VPIII Microbial Identification Test.

BD Affirm VPIII A ttS PreferreD USe Vaginosis screen for Candida albicans, Gardnerella vaginalis and Trichomonas vaginalis. AlSO A CCePt ABle fOr N/A SPeCIAl COnSIDerAtIOnS The specimen collection swab must be submitted in the tube for the testing to be completed. thin Prep PreferreD USe Collection and transport of samples for pap smear. Description. Combine with BD Affirm VPIII Ambient Temperature Transport System (Cat. No. 23-025-604) For detection and identification of Candida species, Gardnerella vaginalis, and Trichomonas vaginalis nucleic acid in vaginal fluid specimens from vaginitis/vaginosis patients; Uses two distinct single-stranded nucleic acid probes for each organism: a capture probe and color development probe

AFFIRMв„ў BV/Vaginitis Panel DNA Probe Diagnostic

bd affirm collection instructions

Bd Gram Stain Kit Instructions WordPress.com. Using the BD Affirm collection kit, follow the collection instructions. This is a DNA test for Gardnerella vaginalis, Candida species, and Trichomonas vaginalis. Transport at room temperature after collection. or sterile body fluids., Ensure that patients read the Patient Collection Instructions before providing them with a collection kit. Instructions for vaginal swab specimen collection: 1. Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima Vaginal Swab Specimen Collection Kit. 2.

BACTERIAL VAGINOSIS/VAGINITIS PANEL (BD AFFIRM. Collection Instructions before providing them with a collection kit. Instructions for penile meatal swab specimen collection: 1. Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima Multitest Swab Specimen Collection Kit. 2. Hold the swab, placing your, BD BD Affirm VPIII Microbial Identification Test - Identification Tests, Model 446252, Each-A direct specimen RNA probe-based diagnostic test for the differential detection and identification of the causative agents for vaginitis. The RNA probe techn.

BD Affirm Collection and Transport System for Triple Screen

bd affirm collection instructions

Aptima Multitest Swab Specimen Collection Kit Hologic. BD MAX™ Vaginal Panel Elevate the standard of care for Women’s Health. Vaginal infections are among the most common reasons for which women in the United States seek medical care–resulting in approximately 10 million visits to physician offices annually. 1,2,3,4 Traditional diagnostic techniques tend to be subjective with variable sensitivity and specificity. 2,5,6 This potentially leads https://en.wikipedia.org/wiki/Medical_prescription Your healthcare provider should give you instructions and make sure you understand what to do before you start. This page explains the procedure. (Illustrations courtesy of Gen-Probe Incorporated, San Diego CA) To collect a vaginal swab for gonorrhea/chlamydia testing: 1. Thoroughly wash your hands before starting. Undress from the waist down. 2..

bd affirm collection instructions

  • Bd Gram Stain Kit Instructions WordPress.com
  • BD BD Affirm VPIII Microbial Identification Test

  • Follow instructions on the next page before placing in the sample collection tube (SCT) into the sample transport bag, this is very important. Once collected the specimen must be processed within 72 hours. Figure 1 Figure 2 Helping ail people live healthy lives . BD Affirm M VPIII Collection and Transport BD AffirmTM VPIII Ambient Temperature Transport System For transport of vaginal specimens These instructions describe how to operate your BD FACSCalibur™ flow cytometer using BD FACStation™ software. BD Biosciences recommends that first-time users take advantage of operator training offered with the sale of every new instrument. The BD FACSCalibur Instructions for Use assumes you have a working

    Affirm VPIII Ambient Temperature Transport System (ATTS) Collection. Break ampule in ATTS reagent dropper and dispense reagent into sample collection tube. Using transport swab provided, obtain a sample from the posterior vaginal fornix. Immediately place swab in collection tube. Break swab shaft at prescored line. Press cap onto collection tube until it snaps in place. Region Selector. Select your country. or visit BD's Worldwide Site. Remember my country. BD is a leading medical technology company that advances human health in every corner of the world by improving medical research, diagnostics and the delivery of care. BD leads in health care safety - including medication safety, health care worker safety and infection prevention - as well as the

    Place swab immediately in the AFFIRM™ VPIII Ambient Temperature Transport System (ATTS). See the alphabetical listing in the Microbiology section of Specimen Collection and Handling for further instructions. Minimum Volume. One BD AFFIRM™ ATTS swab. Transport Container. BD AFFIRM™ VPIII Ambient Temperature Transport System (ATTS Becton Dickinson BD Affirm - Molecular Biology Analyzer Information . Highlights ♦ Original instrumentation provided by BD Bactec. ♦ Diamond Down-To-Frame® refurbishment provided. ♦ Refurbishment includes disassembly and total restoration. ♦ Process continues with assembly, repair, and diagnostics. ♦ Certification concludes with calibration, QC and QA validation.

    Gibson Bioscience is the exclusive manufacturer of the Tri-Valent® Swab, a positive control swab for use with DNA Probe Detection Kits. The Tri-Valent® Swab functions as a tri-analyte that can be processed following the exact methods for a patient specimen. Description. For use only with BD Affirm VPIII Microbial Identification Test (23-025-603) Stabilizes nucleic acid of Candida species, Gardnerella vaginalis, and Trichomonas vaginalis during specimen transport at ambient temperature (15-30°C) for up to 72 hours; Use only with those specimens where transport times are expected to exceed one hour at ambient temperature (15-30°C) or four hours

    BD Affirm™ Collection and Transport System for Triple Screen. Date: March 19, 2018 . The BD Affirm™ Test is designed to detect nucleic acids of Candida, Gardnerella vaginalis and Trichomonas vaginalis in vaginal swab specimens.. The BD Affirm™ Collection and Transport System stabilize s the nucleic acid of these organisms in BD Affirm™ VPIII Collection and Transport BD Affirm™ VPIII Ambient Temperature Collection System Figure 1 Figure 2 VAGINAL SAMPLE COLLECTION For collection of vaginal specimens for use in the BD Affirm VPIII Microbial Identification Test for Candida, Gardnerella and Trichomonas. See reverse side for transport procedures.

    bd affirm collection instructions

    Affirm VPIII Vaginitis Microbial Infection Test Components by BD A molecular system for the detection of vaginitis, the Affirm VPIII helps achieve objective results for better patient care through an accurate, easy-to-use, automated platform Affirm VPIII Ambient Temperature Transport System (ATTS) Collection. Break ampule in ATTS reagent dropper and dispense reagent into sample collection tube. Using transport swab provided, obtain a sample from the posterior vaginal fornix. Immediately place swab in collection tube. Break swab shaft at prescored line. Press cap onto collection tube until it snaps in place.

    Gibson Bioscience Tri-ValentВ® Swabs Control Swabs for

    bd affirm collection instructions

    APTIMAВ® Vaginal Swab Specimen Collection Kit hologic.com. 7. Open provided collection swab. ONLY BD Affirm swab can be used. 8. Collect patient sample using unlubricated speculum (NO JELLY or WATER) and provided. Affirm swab from posterior vaginal fornix. Swab lateral vaginal wall while removing swab. 9. Drop swab immediately into tube until swab tip touches the bottom of the tube. 10. "Snap" off, BD Affirm™ VPIII Collection and Transport BD Affirm™ VPIII Ambient Temperature Collection System Figure 1 Figure 2 VAGINAL SAMPLE COLLECTION For collection of vaginal specimens for use in the BD Affirm VPIII Microbial Identification Test for Candida, Gardnerella and Trichomonas. See reverse side for transport procedures..

    ESwab as an Optional Collection Device for Use with the

    BD BD Affirm VPIII Microbial Identification Test. BD Affirm™ VPIII Collection and Transport BD Affirm™ VPIII Ambient Temperature Collection System Figure 1 Figure 2 VAgInAl SAmPle ColleCTIon For collection of vaginal specimens for use in the BD Affirm™ VPIII Microbial Identification Test for Candida, Gardnerella and Trichomonas.See reverse side for transport procedures., Using the BD Affirm collection kit, follow the collection instructions. This is a DNA test for Gardnerella vaginalis, Candida species, and Trichomonas vaginalis. Transport at room temperature after collection. or sterile body fluids..

    Place swab immediately in the AFFIRM™ VPIII Ambient Temperature Transport System (ATTS). See the alphabetical listing in the Microbiology section of Specimen Collection and Handling for further instructions. Minimum Volume. One BD AFFIRM™ ATTS swab. Transport Container. BD AFFIRM™ VPIII Ambient Temperature Transport System (ATTS The BD Affirm ™ VPIII microbial identification system is a molecular system for the detection of vaginitis. It helps achieve objective results for better patient care through an accurate, easy-to-use, automated platform. Traditional methods for the detection of vaginitis, such as microscopy, Gram staining and culture, are subjective.

    BD Affirm™ Collection and Transport System for Triple Screen. Date: March 19, 2018 . The BD Affirm™ Test is designed to detect nucleic acids of Candida, Gardnerella vaginalis and Trichomonas vaginalis in vaginal swab specimens.. The BD Affirm™ Collection and Transport System stabilize s the nucleic acid of these organisms in BD MAX™ Vaginal Panel Elevate the standard of care for Women’s Health. Vaginal infections are among the most common reasons for which women in the United States seek medical care–resulting in approximately 10 million visits to physician offices annually. 1,2,3,4 Traditional diagnostic techniques tend to be subjective with variable sensitivity and specificity. 2,5,6 This potentially leads

    01/11/2013 · A commercially available, nonamplified, nucleic acid probe-based test system (BD Affirm VPIII) was compared with nucleic acid amplification (NAA)-based assays for determining the etiology of vaginitis in a cohort of 323 symptomatic women. First, a semiquantitative, multiplexed PCR assay (BV-PCR) and the Affirm VPIII Gardnerella vaginalis test were compared with a unified bacterial-vaginosis 7. Open provided collection swab. ONLY BD Affirm swab can be used. 8. Collect patient sample using unlubricated speculum (NO JELLY or WATER) and provided. Affirm swab from posterior vaginal fornix. Swab lateral vaginal wall while removing swab. 9. Drop swab immediately into tube until swab tip touches the bottom of the tube. 10. "Snap" off

    Your healthcare provider should give you instructions and make sure you understand what to do before you start. This page explains the procedure. (Illustrations courtesy of Gen-Probe Incorporated, San Diego CA) To collect a vaginal swab for gonorrhea/chlamydia testing: 1. Thoroughly wash your hands before starting. Undress from the waist down. 2. Becton Dickinson BD Affirm - Molecular Biology Analyzer Information . Highlights ♦ Original instrumentation provided by BD Bactec. ♦ Diamond Down-To-Frame® refurbishment provided. ♦ Refurbishment includes disassembly and total restoration. ♦ Process continues with assembly, repair, and diagnostics. ♦ Certification concludes with calibration, QC and QA validation.

    Test Kit Affirm™ VPIII Microbial Identification Candida Species / Gardnerella Vaginalis / Trichomonas Vaginalis Vaginal Secretion Sample 24 Tests BD 446252 BD 446252 - … BD Affirm VPIII Vaginitis/Vaginosis Panel Overview February 2009 Associated Pathologists/PathGroup Labs is now offering the BD Affirm VPIII test for Vaginitis/Vaginosis. This test is available for samples collected using BD Affirm Ambient Temperature transport swabs and ThinPrep collected specimens.

    BD Affirm VPIII Vaginitis/Vaginosis Panel Overview February 2009 Associated Pathologists/PathGroup Labs is now offering the BD Affirm VPIII test for Vaginitis/Vaginosis. This test is available for samples collected using BD Affirm Ambient Temperature transport swabs and ThinPrep collected specimens. BD Affirm™ VPIII Collection and Transport BD Affirm™ VPIII Ambient Temperature Collection System Figure 1 Figure 2 VAgInAl SAmPle ColleCTIon For collection of vaginal specimens for use in the BD Affirm™ VPIII Microbial Identification Test for Candida, Gardnerella and Trichomonas.See reverse side for transport procedures.

    Place swab immediately in the AFFIRM™ VPIII Ambient Temperature Transport System (ATTS). See the alphabetical listing in the Microbiology section of Specimen Collection and Handling for further instructions. Minimum Volume. One BD AFFIRM™ ATTS swab. Transport Container. BD AFFIRM™ VPIII Ambient Temperature Transport System (ATTS The BD Affirm ™ VPIII microbial identification system is a molecular system for the detection of vaginitis. It helps achieve objective results for better patient care through an accurate, easy-to-use, automated platform. Traditional methods for the detection of vaginitis, such as microscopy, Gram staining and culture, are subjective.

    446252 BD Affirm™ VPIII Microbial Identification Test, 24 tests 446257 BD Affirm™ VPIII Microbial Identification Test, 120 tests Danger h225 Highly flammable liquid and vapor. h302 Harmful if swallowed. h315 Causes skin irritation. h319 Causes serious eye irritation. h336 May cause drowsiness or dizziness. BD Affirm VPIII A ttS PreferreD USe Vaginosis screen for Candida albicans, Gardnerella vaginalis and Trichomonas vaginalis. AlSO A CCePt ABle fOr N/A SPeCIAl COnSIDerAtIOnS The specimen collection swab must be submitted in the tube for the testing to be completed. thin Prep PreferreD USe Collection and transport of samples for pap smear.

    Follow instructions on the next page before placing in the sample collection tube (SCT) into the sample transport bag, this is very important. Once collected the specimen must be processed within 72 hours. Figure 1 Figure 2 Helping ail people live healthy lives . BD Affirm M VPIII Collection and Transport BD AffirmTM VPIII Ambient Temperature Transport System For transport of vaginal specimens Description. For use only with BD Affirm VPIII Microbial Identification Test (23-025-603) Stabilizes nucleic acid of Candida species, Gardnerella vaginalis, and Trichomonas vaginalis during specimen transport at ambient temperature (15-30°C) for up to 72 hours; Use only with those specimens where transport times are expected to exceed one hour at ambient temperature (15-30°C) or four hours

    BD Affirm™ VPiii ColleCtion GuiDe 1. retrieve BD Affirm Kit for collection. 2. open kit. remove contents. 5. “CrACK” inner ampule by squeezing 8. Collect patient sample using 11. “CAP” firmly so there is no gap 3. label tube with reQuireD 6. invert and dispense all fluid from dropper 9. Drop swab immediately in … The BD Affirm ™ VPIII microbial identification system is a molecular system for the detection of vaginitis. It helps achieve objective results for better patient care through an accurate, easy-to-use, automated platform. Traditional methods for the detection of vaginitis, such as microscopy, Gram staining and culture, are subjective.

    Description. For use only with BD Affirm VPIII Microbial Identification Test (23-025-603) Stabilizes nucleic acid of Candida species, Gardnerella vaginalis, and Trichomonas vaginalis during specimen transport at ambient temperature (15-30°C) for up to 72 hours; Use only with those specimens where transport times are expected to exceed one hour at ambient temperature (15-30°C) or four hours The three main categories of vaginitis are bacterial vaginosis (BV), yeast vaginitis (candidiasis), and T. vaginalis vaginitis (trichomoniasis). This test will detect all three agents from a single swab specimen. The swab is a special collection device called the AFFIRM(TM) VPIII …

    BD Affirm VPIII Collection and Transport Temperature Collection System For collection of vaginal specimens for use in the BD Affirm VPIII Microbial Identification Test for Candida, Gardnere//a and Trichomonas. See reverse side for transport procedures. VAGINAL SAMPLE COLLECTION Sample collection is a critical step. Personnel collecting vaginal fluid specimens should be well trained to … Container/Tube: Vaginal swab collected using the BD Affirm VPIII Ambient Temperature Transport System. Specimen Volume: Entire specimen Collection Instructions: 1. Open the seal on outer plastic pouch of Affirm VPIII ATTS and remove all components. 2. Tear open the foil pouch and remove the ATTS Reagent Dropper. 3. Break the ampule in the ATTS

    Collection Instructions before providing them with a collection kit. Instructions for penile meatal swab specimen collection: 1. Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima Multitest Swab Specimen Collection Kit. 2. Hold the swab, placing your Ensure that patients read the Patient Collection Instructions before providing them with a collection kit. Instructions for vaginal swab specimen collection: 1. Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima Vaginal Swab Specimen Collection Kit. 2

    BD Affirm Collection and Transport System for Triple Screen

    bd affirm collection instructions

    Collections et demandes d'informations BD Gest' -. Collection Instructions before providing them with a collection kit. Instructions for penile meatal swab specimen collection: 1. Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima Multitest Swab Specimen Collection Kit. 2. Hold the swab, placing your, These instructions describe how to operate your BD FACSCalibur™ flow cytometer using BD FACStation™ software. BD Biosciences recommends that first-time users take advantage of operator training offered with the sale of every new instrument. The BD FACSCalibur Instructions for Use assumes you have a working.

    Microbiology Specimen Collection Guide Find A Test

    bd affirm collection instructions

    Bacterial Vaginosis/Vaginitis Panel Test Detail Quest. Des milliers de références de BD anciennes, BD rares, BD d'occasion, BD de collection, éditions originales, dédicaces, planches originales... https://en.wikipedia.org/wiki/Medical_prescription Container/Tube: Vaginal swab collected using the BD Affirm VPIII Ambient Temperature Transport System. Specimen Volume: Entire specimen Collection Instructions: 1. Open the seal on outer plastic pouch of Affirm VPIII ATTS and remove all components. 2. Tear open the foil pouch and remove the ATTS Reagent Dropper. 3. Break the ampule in the ATTS.

    bd affirm collection instructions


    7. Open provided collection swab. ONLY BD Affirm swab can be used. 8. Collect patient sample using unlubricated speculum (NO JELLY or WATER) and provided. Affirm swab from posterior vaginal fornix. Swab lateral vaginal wall while removing swab. 9. Drop swab immediately into tube until swab tip touches the bottom of the tube. 10. "Snap" off BD Affirm™ VPiii ColleCtion GuiDe 1. retrieve BD Affirm Kit for collection. 2. open kit. remove contents. 5. “CrACK” inner ampule by squeezing 8. Collect patient sample using 11. “CAP” firmly so there is no gap 3. label tube with reQuireD 6. invert and dispense all fluid from dropper 9. Drop swab immediately in …

    03/07/2017 · Bacterial Vaginosis/Vaginitis Panel (BD Affirm™) Order Name VAG MOLEC Test Number 4604810 Revision Date 07/03/2017. Test Name Methodology LOINC Code The BD Affirm ™ VPIII microbial identification system is a molecular system for the detection of vaginitis. It helps achieve objective results for better patient care through an accurate, easy-to-use, automated platform. Traditional methods for the detection of vaginitis, such as microscopy, Gram staining and culture, are subjective.

    Affirm VPIII Ambient Temperature Transport System (ATTS) Collection. Break ampule in ATTS reagent dropper and dispense reagent into sample collection tube. Using transport swab provided, obtain a sample from the posterior vaginal fornix. Immediately place swab in collection tube. Break swab shaft at prescored line. Press cap onto collection tube until it snaps in place. Transport System, the Affirm VPIII Sample Collection Set or the swabs provided in the Affirm VPIII Microbial Identification Test Kit. Separate swabs should be used for other tests, e.g. culture or microscopic slide samples. BD Affirm VPIII Ambient Temperature Transport System for EXTENDED TIME:

    BD Affirm VPIII Vaginitis/Vaginosis Panel Overview February 2009 Associated Pathologists/PathGroup Labs is now offering the BD Affirm VPIII test for Vaginitis/Vaginosis. This test is available for samples collected using BD Affirm Ambient Temperature transport swabs and ThinPrep collected specimens. BD Affirm™ VPiii ColleCtion GuiDe 1. retrieve BD Affirm Kit for collection. 2. open kit. remove contents. 5. “CrACK” inner ampule by squeezing 8. Collect patient sample using 11. “CAP” firmly so there is no gap 3. label tube with reQuireD 6. invert and dispense all fluid from dropper 9. Drop swab immediately in …

    Effective Monday, July 22 nd, Women’s Health Laboratories will begin converting our molecular testing approach for the detection of Vagionosis.We will be transitioning from the previous Access Genetics PCR based assay to the FDA-approved Becton Dickenson (BD) Affirm™ VPIII Microbial Identification System. Description. For use only with BD Affirm VPIII Microbial Identification Test (23-025-603) Stabilizes nucleic acid of Candida species, Gardnerella vaginalis, and Trichomonas vaginalis during specimen transport at ambient temperature (15-30°C) for up to 72 hours; Use only with those specimens where transport times are expected to exceed one hour at ambient temperature (15-30°C) or four hours

    Des milliers de références de BD anciennes, BD rares, BD d'occasion, BD de collection, éditions originales, dédicaces, planches originales... The BD Affirm VPIII microbial identification test system (BD, Franklin Lakes, NJ) is widely used by many clinical laboratories and as an office-based test for gynecologists to diagnose vaginal infections . The Affirm system provides its own collection device specific to that test. However, clinicians often order additional tests for patient care.

    BD BD Affirm VPIII Microbial Identification Test - Identification Tests, Model 446252, Each-A direct specimen RNA probe-based diagnostic test for the differential detection and identification of the causative agents for vaginitis. The RNA probe techn Your healthcare provider should give you instructions and make sure you understand what to do before you start. This page explains the procedure. (Illustrations courtesy of Gen-Probe Incorporated, San Diego CA) To collect a vaginal swab for gonorrhea/chlamydia testing: 1. Thoroughly wash your hands before starting. Undress from the waist down. 2.

    The BD Affirm ™ VPIII microbial identification system is a molecular system for the detection of vaginitis. It helps achieve objective results for better patient care through an accurate, easy-to-use, automated platform. Traditional methods for the detection of vaginitis, such as microscopy, Gram staining and culture, are subjective. Specimen collection. Start with quality specimen collection to achieve better results. For more than 60 years, BD Life Sciences – Preanalytical Systems has advanced the science of specimen collection to help laboratory tests become the foundation for 70% of all medical decisions. 1 Today, the gold standard in sample collection is the BD Vacutainer ® product family, which U.S. hospitals rely

    BD Affirm™ VPIII Collection and Transport BD Affirm™ VPIII Ambient Temperature Collection System Figure 1 Figure 2 VAGINAL SAMPLE COLLECTION For collection of vaginal specimens for use in the BD Affirm VPIII Microbial Identification Test for Candida, Gardnerella and Trichomonas. See reverse side for transport procedures. Container/Tube: Vaginal swab collected using the BD Affirm VPIII Ambient Temperature Transport System. Specimen Volume: Entire specimen Collection Instructions: 1. Open the seal on outer plastic pouch of Affirm VPIII ATTS and remove all components. 2. Tear open the foil pouch and remove the ATTS Reagent Dropper. 3. Break the ampule in the ATTS

    bd affirm collection instructions

    Using the BD Affirm collection kit, follow the collection instructions. This is a DNA test for Gardnerella vaginalis, Candida species, and Trichomonas vaginalis. Transport at room temperature after collection. or sterile body fluids. These instructions describe how to operate your BD FACSCalibur™ flow cytometer using BD FACStation™ software. BD Biosciences recommends that first-time users take advantage of operator training offered with the sale of every new instrument. The BD FACSCalibur Instructions for Use assumes you have a working